BIONEST® reactor
Aerator (air pump)
The lter of each aerator (air pump) must be cleaned periodically. According to the aerators (air
pumps) location (dusty area), a more frequent cleaning by the owner may become necessary; a
clogged lter may cause overheating or pump failure. To clean the air lter:
1. Disconnect the aerator (air pump) and BIOLARM® power supplies.
2. Remove the aerator (air pump) cover by unscrewing the screw and pulling on the cover.
3. Remove and clean the lter. If required, clean with soapy water. If cleaned with water,
make sure the lter is well rinsed under clear water and dried thoroughly before
putting it back into place.
4. Install the lter and cover making sure the seal joint is positioned correctly.
Replace previously removed screw.
5. Turn on aerator (air pump) and BIOLARM® power supplies.
Attention : Please make sure the aerator (air pump) is installed in a well ventilated room,
away from dust.
Screw
Cover
Filter
Pump casing