1. Unplug cleaner from electrical outlet
2. Using a screwdriver, remove the two screws as shown and lift off the lens.
3. Remove the bulb from the socket by pushing in gently and turning it counterclockwise. Install the
new bulb by pushing it gently into the socket and turning clockwise.
4. Reposition lens and secure with the two screws.
Clearing Clogs
Low suction or poor pickup may be due to a clog in the vacuum cleaner. If you notice a change in the
sound of the motor or a reduction in the spinning action, check for clogs.
1. Unplug cleaner from electrical outlet.
2. Empty Dirt Container.
3. Check Upper Tank for build up or clogs.
4. Remove the Upper Tank and check the suction inlet for a clog.
5. Grasp the Quick Reach Handle and lift Hose Wand to separate from the suction opening. Check for
a clog in the Base, the Wand or the Hose.
6. Remove the screw attaching the Hose Wand Base to the vacuum. Straighten the Hose Wand Base
and unclog with long,
narrow object.
7. If the clog persists, follow the instructions for Checking the Rotating Floor Brush on page 10 and
inspect the Air Passageway for obstructions.