3.19 MIRROR
You can mirror traffic from any source port to a target port for real-time analysis. You can then attach a logic analyzer or RMON
probe to the target port and study the traffic crossing the source port in a completely unobtrusive manner.
Mirror Configuration monitors the traffic of the network. For example, we assume that Port A and Port B are Monitoring Port and
Monitored Port respectively, thus, the traffic received by Port B will be copied to Port A for monitoring.
WEB INTERFACE
To configure the Mirror in the web interface:
1. Click Configuration, Mirroring.
2. Scroll to select the Port to mirror on which port.
3. Scroll to disabled, enable, TX Only, and RX Only to set the Port mirror mode.
4. Click save to save the setting.
5. To cancel the setting. click the Reset button. It will revert to previously saved values.
FIGURE 3-91. MIRROR CONFIGURATION SCREEN
Parameter description:
Port to mirror on: Port to mirror is also known as the mirror port. Frames from ports that have either source (rx) or destination (tx)
mirroring enabled are mirrored on this port. Disabled disables mirroring.