Page 5
SAFETY INFORMATION
USE OF EXTENSION CORDS WITH
DEHUMIDIFIER
Only use a grounded extension cord that is rated at least 7.8 amps
and has a third-wire ground. When a long extension cord is used to
connect the dehumidier, a voltage drop occurs. The longer the cord,
the greater the voltage drop. This results in less voltage being supplied
to the dehumidier and increases the amount of current (amp) draw
or reduces performance. A heavier cord with a larger wire size will
reduce the voltage drop. Be sure to choose a cord that will supply
enough voltage to operate the dehumidier. The table below indicates
appropriate gauge for extension cords.
WARNING: Keep electrical cords in good condition. Do not use worn, bare, or
frayed cords because they can cause electrical shock.
WARNING: Operating equipment at low voltage can cause it to overheat. Using
an excessively long extension cord can cause the cord to overheat.
Minimum Gauge for Cord Sets
Ampere Rating
Volts
Total Length of Cord in Feet (meters)
120V 25 (7.6) 50 (15.2) 100 (30.5) 150 (45.7)
240V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
More than
Not more
than
AWG
0 6 18 16 16 14
6 10 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not Recommended