HydroLift
Maintenance
11.1 Maintenance schedule
Lifting systems in continuous operation or in particularly polluted surroundings are to be more
frequently maintained.
After replacing safety-relevant parts, perform additional checks during maintenance work and
document them in the supplied test log.
Daily:
Check electrical cables for damage.
Charge batteries. (10.9)
After work, completely lower the lifting system and secure against
unauthorised use.
Clean lifting system and working area.
Monthly:
Check hydraulic oil level, top up if necessary. (11.3)
Check controls on functioning and electrical cables for damage.
Check the tightness of the hydraulic components.
Lubricate rollers.
Perform a function test without load.
Check emergency stop key.
Check the function of the safety catch.
For HydroLift 8.2 only: clean and lubricate the wheel fork notch.
Yearly:
Perform security check.
Every 2 years:
Change oil (11.5)
Every 6 years:
Change the hydraulic hoses. (11.7)