UNDERCOUNTER REFRIGERATION
MODEL: UCR140 – UCF140
OPERATING INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the Blizzard UCR140 and is the answer not in the manual?

Summary

Safety Instructions

Installation Guide

Electrical Connection Procedures

Startup and Initial Operation

Maintenance and Care

Cleaning the Appliance

Instructions for cleaning the interior, exterior, and condenser of the chiller/freezer.

Power Failure Management

Guidance on handling power outages and long-term non-usage.

Troubleshooting Common Issues

Unit Not Working Properly

Checks for electrical outlet, condenser, and circuit breaker.

Excessive Noise Diagnosis

Troubleshooting steps for unusual noises, focusing on leveling.

Frequent Compressor Cycling

Factors influencing compressor on/off frequency, including temperature and door seals.

Normal Operational Sounds

Clarification that gurgling sounds are normal refrigerant flow.

Accessory Parts List

Summary

Safety Instructions

Installation Guide

Electrical Connection Procedures

Startup and Initial Operation

Maintenance and Care

Cleaning the Appliance

Instructions for cleaning the interior, exterior, and condenser of the chiller/freezer.

Power Failure Management

Guidance on handling power outages and long-term non-usage.

Troubleshooting Common Issues

Unit Not Working Properly

Checks for electrical outlet, condenser, and circuit breaker.

Excessive Noise Diagnosis

Troubleshooting steps for unusual noises, focusing on leveling.

Frequent Compressor Cycling

Factors influencing compressor on/off frequency, including temperature and door seals.

Normal Operational Sounds

Clarification that gurgling sounds are normal refrigerant flow.

Accessory Parts List

Overview

This document provides operating instructions for the Blizzard UCR140 and UCF140 undercounter refrigeration units, which function as either chillers or freezers. These appliances are designed for commercial use, offering reliable temperature control for various storage needs. The manual outlines essential safety precautions, installation guidelines, startup procedures, maintenance tips, and troubleshooting advice to ensure optimal performance and longevity of the unit.

Function Description

The Blizzard UCR140 and UCF140 are undercounter refrigeration units primarily designed for storing food and beverages at controlled temperatures. The UCR140 model functions as a chiller, maintaining temperatures between 0°C and +8°C, while the UCF140 model operates as a freezer, capable of reaching temperatures between -16°C and -24°C. This dual functionality allows users to select the appropriate model based on their specific storage requirements, whether it's keeping items chilled or frozen.

The core function of these units relies on a refrigeration circuit that cools the interior compartment. This process involves a compressor, condenser, and evaporator working in conjunction with a refrigerant. The electronic thermostat allows precise temperature control, ensuring that stored items are kept at their optimal conditions. The units are designed to be placed under a counter, making them space-efficient for commercial kitchens, bars, or other establishments where compact refrigeration is needed.

The internal design includes shelves and a basket for organized storage, facilitating easy access and inventory management. For the freezer model (UCF140), an ice-making box and a frost scraper are included, indicating its capability for freezing and the need for occasional defrosting, although the manual also mentions mechanisms to accelerate defrosting. The overall construction aims for durability and efficiency, crucial for demanding commercial environments.

Usage Features

The Blizzard UCR140 and UCF140 units are designed for straightforward operation, with several features enhancing user experience and efficiency.

Temperature Control: The electronic thermostat is a key usage feature, allowing users to precisely set the desired temperature. By pressing the "SET" key for more than three seconds, the display flashes, enabling the user to adjust the temperature. For chillers (UCR140), the range is 0°C to +8°C, while for freezers (UCF140), it's -16°C to -24°C. This flexibility ensures that a wide variety of products can be stored at their ideal temperatures.

Initial Startup: For optimal performance, the manual recommends operating the chiller/freezer for three hours after plugging it in for the first time. This initial run helps the unit stabilize and ensures the refrigeration system is functioning correctly before loading it with items.

Storage Organization: The inclusion of shelves and a basket (three of each for both models) allows for efficient organization of stored items. This helps in maximizing the internal space and provides easy access to products, which is particularly beneficial in busy commercial settings. The UCF140 also comes with an ice-making box, adding to its utility as a freezer.

Placement Guidelines: Proper placement is crucial for efficient operation. The units should be located in a dry and airy place, away from walls by at least four inches to ensure adequate air circulation around the condenser unit. This prevents overheating and maintains cooling efficiency. The appliance should also be placed on a leveled countertop to ensure stability and proper functioning.

Door Management: Users are advised to minimize the frequency of door opening, especially during power failures, to maintain internal temperature stability. The door gasket is designed to create a good seal, and users should ensure the door is closed completely to prevent cold air from escaping, which can lead to increased energy consumption and reduced cooling performance.

Power Connection: The units require a suitable power outlet (AC220 - 240V/50Hz, 13amps) with proper grounding. Users are warned against plugging other electrical appliances into the chiller/freezer's outlet, emphasizing the need for a dedicated power source to prevent electrical overload and ensure safe operation.

Quiet Operation: The manual notes that gurgling sounds caused by the flow of refrigerant are normal at the end of each cooling cycle, reassuring users that such sounds do not indicate a malfunction. This helps manage user expectations regarding the unit's operational sounds.

Maintenance Features

Regular maintenance is essential for the longevity and efficient operation of the Blizzard UCR140 and UCF140 units. The manual provides clear instructions for cleaning and handling specific situations like power failures or extended periods of non-use.

Cleaning Procedures:

  • Safety First: Before any cleaning, the appliance must be unplugged. Users are specifically instructed to grasp the plug firmly and pull it straight out from the power outlet, rather than pulling the power cord, to prevent damage.
  • Interior Cleaning: The interior surfaces should be cleaned with a damp cloth and a neutral cleanser. Abrasive or flammable cleaning products are to be avoided to prevent damage to the unit's surfaces.
  • Condenser Cleaning: The condenser unit, located at the back of the appliance, requires regular cleaning. It should be cleaned at least once a month using a vacuum cleaner and a brush to remove dust accumulation. This is critical for maintaining cooling efficiency, as a dusty condenser can impede heat dissipation and force the compressor to work harder, leading to higher energy consumption and potential wear.
  • Avoid Sharp Objects: Users are explicitly warned against using sharp or pointed objects for cleaning, as these can damage the interior or exterior surfaces of the unit.

Handling Power Failures:

  • Minimize Door Opening: During a power failure, users are advised to minimize opening the door to help retain the cold air inside the unit. This can significantly slow down the rate at which the internal temperature rises.
  • Extended Outages: For extended power outages, the manual suggests following proper procedures regarding the storage of cans (presumably referring to the contents). While not detailed, this implies that perishable items might need to be moved or monitored closely if the power remains off for a long time.

Preparation for Extended Non-Use:

  • Empty and Unplug: If the chiller/freezer will be unused for an extended period, it is best to remove all contents, unplug the unit, and clean it thoroughly.
  • Door Ajar: Crucially, the door should be left open after cleaning. This prevents the formation of condensation, mold, and unpleasant odors inside the unit, ensuring it remains fresh and hygienic for future use.

Refrigerant Circuit Integrity: Users are warned not to damage the refrigerant circuit. This is a critical component of the refrigeration system, and any damage can lead to refrigerant leaks, rendering the unit inoperable and potentially posing environmental hazards.

Ventilation Maintenance: Maintaining clear ventilation openings, both in the appliance enclosure and any built-in structure, is emphasized. Blocked vents can restrict airflow, leading to reduced efficiency and potential overheating of the compressor.

Disposal of Flammable Insulation Material: The manual notes that flammable insulation material must be disposed of by a specialized agency. This highlights the importance of proper handling and disposal of the unit at the end of its life cycle, adhering to environmental regulations.

Cord Replacement: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person. Users are explicitly warned not to attempt to repair the cord themselves, ensuring safety and proper functioning.

In summary, the Blizzard UCR140 and UCF140 are robust undercounter refrigeration units designed for commercial applications. Their user-friendly temperature controls, efficient storage solutions, and clear maintenance guidelines make them a practical choice for businesses requiring reliable chilling or freezing capabilities. Adherence to the provided instructions ensures safe operation, optimal performance, and extended product life.

Blizzard UCR140 Specifications

General IconGeneral
CategoryRefrigerator
BrandBlizzard
ModelUCR140
Energy RatingA+
Number of Doors1
ColorWhite
Weight32kg
Dimensions (H x W x D)850 x 550 x 580 mm

Related product manuals