- 27 -
ers. Their power consumption will be increased unnecessarily by the pro-
duced heat.
A space of at least 50 mm must remain free for cooling under the entire
cut-out space for the appliance. No heat-sensitive items (base cabinet,
drawer, etc.) may be located in this space. Any existing side walls or draw-
er boxes must be removed or cut out accordingly.
The work surface must be at least 30 mm thick and 620 mm deep, must
be level, and must be sealed on the wall side against liquid overow.
The glass-ceramic hob must be framed on all sides by at least 50 mm of
work surface.
The work surface, back walls, veneers, plastic coatings, and glues used
must be sufciently heat-resistant (up to 100 °C).
The cut-out space may be max. 750 x 495 mm.
The appliance shall be installed so that sufcient air circulation is assured
(refer to the following gure).
Min. dimensions for suf-
cient air circulation:
A Distance to wall
cabinets
760 mm
B Free space
under the hob
50 mm
C Distance to the
wall
30 mm
D Air inlet 30 mm
E Air outlet 10 mm