- 27 -
ers. Their power consumption will be increased unnecessarily by the pro-
duced heat.
• A space of at least 50 mm must remain free for cooling under the entire
cut-out space for the appliance. No heat-sensitive items (base cabinet,
drawer, etc.) may be located in this space. Any existing side walls or draw-
er boxes must be removed or cut out accordingly.
• The work surface must be at least 30 mm thick and 620 mm deep, must
be level, and must be sealed on the wall side against liquid overow.
• The glass-ceramic hob must be framed on all sides by at least 50 mm of
work surface.
• The work surface, back walls, veneers, plastic coatings, and glues used
must be sufciently heat-resistant (up to 100 °C).
• The cut-out space may be max. 750 x 495 mm.
• The appliance shall be installed so that sufcient air circulation is assured
(refer to the following gure).
Min. dimensions for suf-
cient air circulation:
A Distance to wall
cabinets
760 mm
B Free space
under the hob
50 mm
C Distance to the
wall
30 mm
D Air inlet 30 mm
E Air outlet 10 mm