SAVE THESE INSTRUCTIONS
SELF DIAGNOSTIC
To verify the correct functioning of the keyboard, proceed as
follows:
1. Press and hold “5” until double signal.
2. Press each key consecutively 1-2-3-4-5-6-7-8-9-0 :
Double signal: key properly working
Long signal: damaged key
If no acoustig signal is emitted after pressing and holding
5, the lock is not properly connected to the keypad or the
cable is damaged
LOW BATTERY SIGNAL
A series of signals indicates that the battery is weak and must
be replaced. Only use brand new 9V ALKALINE batteries.
If the battery is exhausted and does not allow opening, follow
the instructions for replacing it.
The lock is equipped with a non-volatile memory: even with the
battery removed it will keep programming.
REPLACING THE BATTERY
1. Open the battery compartment located in the lower part
of the keyboard
2. Gently pull the battery out of the compartment
3. Disconnect the battery, making sure to hold the
connector rmly to avoid detaching the cables from the
connector
4. Connect a new 9V Alkaline battery
5. Insert the new battery into the compartment
6. Close the plastic cover
TIME DELAY PROGRAMMING
Time Delay: waiting time before being able to open the lock
Opening window: time available to enter the code at the
end of the Time Delay
To set the Time Delay and the opening window time,
proceed as follows:
1. Press and hold “3” until double signal
2. Enter Manager code (double signal).
3. Enter Time Delay (2 digits, from 00 to 99 minutes) and
open window values (2 digits, from 0 to 99 minutes).
Example: 0205 to set 2 minutes time delay and 5 minutes
open window.
4. Conrm time delay and open window values.
NOTE: Time Delay can be increased at any moment, can be
decreased only during open window. To delete Time Delay set
0001 and conrm 0001