User and Code Programming
User Code Programming
User no. Option Address Default
01 (master
code 1)
Authority level (0 = master 1, 1 = master 2, 2 =
super, 3 = general, 4 = arm only, 5 = duress, 6 –
15 = no authority)
5994 0
Area selection (BIT mask:
– Area 1 -- 0000 0000 0000 0001 (0x0001)
– Area 2 -- 0000 0000 0000 0010 (0x0002)
– Area 3 -- 0000 0000 0000 0100 (0x0004)
– Area 4 -- 0000 0000 0000 1000 (0x0008)
– Area 5 -- 0000 0000 0001 0000 (0x0010)
– Area 6 -- 0000 0000 0010 0000 (0x0020)
– Area 7 -- 0000 0000 0100 0000 (0x0040)
– Area 8 -- 0000 0000 1000 0000 (0x0080)
– Area 9 -- 0000 0001 0000 0000 (0x0100)
– Area 10 -- 0000 0010 0000 0000 (0x0200)
– Area 11 -- 0000 0100 0000 0000 (0x0400)
– Area 12 -- 0000 1000 0000 0000 (0x0800)
– Area 13 -- 0001 0000 0000 0000 (0x1000)
– Area 14 -- 0010 0000 0000 0000 (0x2000)
– Area 15 -- 0100 0000 0000 0000 (0x4000)
– Area 16 -- 1000 0000 0000 0000 (0x8000))
5995 – 5998
0000
Macro play right (BIT mask:
– Play macro 1 right -- 0001 (0x1)
– Play macro 2 right -- 0010 (0x2)
– Play macro 3 right -- 0100 (0x4))
5999 7
User code 6000 – 6005 258000
Keyfob RFID 6006 – 6014 15
Keyfob button 3 option (0 = not used, 1 =
output control, 2 = STAY arm)
6015 0
reserved 6016
02 (master
code 2)
Authority level 6017 1
Area selection 6018 – 6021 0000
Macro play right 6022 7
User code 6023 – 6028 258100
Keyfob RFID 6029 – 6037 15
Keyfob button 3 option 6038 0
reserved 6039
8.2
8.2.1
AMAX panel Address Programming | en 117
Bosch Sicherheitssysteme GmbH Installation Manual 2015.05 | 06 | F.01U.309.277