Zone Programming
Add/Delete Zone Programming
AMAX 4000 supports up to 64 zones, 16 keypads and 16 areas.
AMAX 3000 / 3000 BE support up to 32 zones, 8 keypads and 8 areas.
AMAX 2100 supports up to 8 zones, 4 keypads and 2 areas.
Zone Module Selection
Zone no. Address Default Zone no. Address Default
01 1432 0 05 1436 0
02 1433 0 06 1437 0
03 1434 0 07 1438 0
04 1435 0 08 1439 0
Value range: 0 = onboard zone, 3 = RF all, 4 = RF RFGB glassbreak, 5 = RF RFUN no magnet,
15 = not used
Zone no. Address Default Zone no. Address Default
09 1440 0 13 1444 0
10 1441 0 14 1445 0
11 1442 0 15 1446 0
12 1443 0 16 1447 0
Value range: 0 = onboard zone (AMAX 4000), 2 = DX2010 zone, 3 = RF all, 4 = RF RFGB
glassbreak, 5 = RF RFUN no magnet, 15 = not used
Zone no. Address Default Zone no. Address Default
17 1448 15 25 1456 15
18 1449 15 26 1457 15
19 1450 15 27 1458 15
20 1451 15 28 1459 15
21 1452 15 29 1460 15
22 1453 15 30 1461 15
23 1454 15 31 1462 15
24 1455 15 32 1463 15
Value range: 1 = Keypad zone (zones 17 to 32 are dedicated to keypad 1 to 16), 2 = DX2010
zone, 3 = RF all, 4 = RF RFGB glassbreak, 5 = RF RFUN no magnet, 15 = not used
Zone no. Address Default Zone no. Address Default
33 1464 0 49 1480 0
34 1465 0 50 1481 0
8.3
8.3.1
AMAX panel Address Programming | en 123
Bosch Sicherheitssysteme GmbH Installation Manual 2015.05 | 06 | F.01U.309.277