Keypad and Area Programming
Keypad Area Programming
Keypad
no.
Address Default Keypad
no.
Address Default
1 1560 – 1561 01 9 1576 – 1577 99
2 1562 – 1563 99 10 1578 – 1579 99
3 1564 – 1565 99 11 1580 – 1581 99
4 1566 – 1567 99 12 1582 – 1583 99
5 1568 – 1569 99 13 1584 – 1585 99
6 1570 – 1571 99 14 1586 – 1587 99
7 1572 – 1573 99 15 1588 – 1589 99
8 1574 – 1575 99 16 1590 – 1591 99
Value range: 00 = master keypad, 01 – 16 = area 01 – 16, 99 = not used
Notice!
The system supports up to 16 master keypads. When the master keypad is not switched to
the corresponding area, no arming/disarming, bypass and alarm reset operations can be
performed on the master keypad. Operations can only be performed in the area when the
master keypad is switched to the corresponding area.
Area Timing Programming
Exit and Entry Delay Time
Area Exit Delay
Address
Default Entry Delay
Address
Default Entry Delay
2 Address
Default
1 0785 – 0787 45 0788 – 0790 30 0791 – 0793 30
2 0794 – 0796 45 0797 – 0799 30 0800 – 0802 30
3 ** 0803 – 0805 45 0806 – 0808 30 0809 – 0811 30
4 ** 0812 – 0814 45 0815 – 0817 30 0818 – 0820 30
5 ** 0821 – 0823 45 0824 – 0826 30 0827 – 0829 30
6 ** 0830 – 0832 45 0833 – 0835 30 0836 – 0838 30
7 ** 0839 – 0841 45 0842 – 0844 30 0845 – 0847 30
8 ** 0848 – 0850 45 0851 – 0853 30 0854 – 0856 30
9 * 0857 – 0859 45 0860 – 0862 30 0863 – 0865 30
10 * 0866 – 0868 45 0869 – 0871 30 0872 – 0874 30
11 * 0875 – 0877 45 0878 – 0880 30 0881 – 0883 30
8.4
8.4.1
8.4.2
132 en | Address Programming AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH