Alarm indication in STAY arm mode (0 = disabled, 1 =
enabled)
1615 1
LCD keypad backlight on when entry delay (0 = disabled,
1 = enabled)
1668 1
Keypad Lockout Programming
Option Address Default
Keypad Lockout (0 = disabled, 1 - 15 = 1 – 15 times) 1592 10
VDS-A
EN=10
System Programming
System Setting Programming
Fault Configuration Programming
Option Address Default
AC fault report delay time (99 =disabled, 0 - 98 = 0 – 98
minutes)
1613 – 1614 60
VDS-A
EN=00-60
Display and prompt tone of date and time fault (0 =
disabled, 1= enabled)
0620 1
Fault prompt tone (0 = disabled, 1= enabled) 0621 1
VDS-A EN=1
Battery Check interval (0 =disabled, 1 – 15 = 1 – 15
minutes)
1612 15
VDS-A
EN=15
Phone line monitor (0 = disabled, 1= enabled) 1599 0
Siren supervision (minutes) 0623 – 0624 00
Siren / PO1+2 Supervision (0 = disabled, 1 = OC1 monitor
enabled, 2 = OC2 monitor enabled, 3 = enabled)
1598 0
AC fault auto reset (0 = disabled, 1= enabled) 1671 0
Communication fault auto reset (0 = disabled, 1=
enabled)
1672 0
Phone fault auto reset (0 = disabled, 1= enabled) 1673 0
General fault auto reset (0 = disabled, 1= enabled) 1674 0
Quick Arm Programming
Option
Address Default
Quick arming (0 = disabled 1= enabled) 1597 1
VDS-A EN=0
8.4.5
8.5
8.5.1
134 en | Address Programming AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH