Installer Access until Next Arming Programming
Option Address Default
Installer access until next arming (0 = disabled, 1 =
enabled)
1660 0
Remote IP Access Programming
Option Address Default
Remote IP access (0 = disabled, 1 = enabled) 0971 0
Force Arm when System is in Trouble Programming
Option
Address Default
Force arm when system is in trouble condition (0 =
disabled, 1 = enabled)
1611 1
Event Record Count per Set/Unset Period Programming
Option
Address Default
Event record count per set/unset period (3 – 10) 1609 10
Language Version Programming
Option
Address Default
Language version of the keypad (0 = default, 1 = EN, 2 =
DE, 3 = ES, 4 = FR, 5 = IT, 6 = PL, 7 = NL, 8 = SE, 9 = TR)
0996 0
Keypad 2 Button Alarm
Option
Address Default
Keypad 2 button alarm (0 = disabled, 1 = enabled) 0992 0
Keypad 2 button panic alarm (0 = disabled, 1 = report, 2 =
siren, 3 = all)
0993 1
Keypad 2 button fire alarm (0 = disabled, 1 = report, 2 =
siren, 3 = all)
0994 1
Keypad 2 button medical alarm (0 = disabled, 1 = report,
2 = siren, 3 = all)
0995 1
System Tamper Indication
Option
Address Default
System tamper indication in area (0 = area 1, 1 = all
areas)
1610 0
AMAX panel Address Programming | en 135