STAY Arm All Areas (only on
master keypad)
[code] + [0] [0] + [*] √ √ √ √ √ √ √
Direct STAY Arm (only on
master keypad
[code] + [2-digit area no.] + [*] √ √ √
Disarm [code] + [#] √ √ √ √ √ √
Disarm One Area (only on
master keypad)
[code] + [2-digit area no.] + [#] √ √ √ √ √ √
Disarm All Areas (only on
master keypad)
[code] + [#] √ √ √ √ √ √
Switch to Master Keypad [code] + [0] [0] [0] + [#] (only on text
keypad)
√ √ √
Switch to Area 01-16 [code] + [0] [2-digit area no.] + [#] (only
on text keypad)
√ √ √
Keypad Emergency Alarm long press [1] and [3] or [*] and [#] * *
Keypad Fire long press [4] and [6] * *
Keypad Medical Alarm long press [7] and [9] √ √
Record Macro 1 [code] + [8] [1] + [#] + sequence to be
recorded + [#] for 3 sec.
√ √ √ √
Record Macro 2 [code] + [8] [2] + [#] + sequence to be
recorded + [#] for 3 sec.
√ √ √ √
Record Macro 3 [code] + [8] [3] + [#] + sequence to be
recorded + [#] for 3 sec.
√ √ √ √
Play Macro 1 [code] + long press [1] / [1] for 3 sec.
(quick macro)
+ + + + + + √
Play Macro 2 [code] + long press [2] / [2] for 3 sec.
(quick macro)
+ + + + + + √
Play Macro 3 [code] + long press [3] / [3] for 3 sec.
(quick macro)
+ + + + + + √
Fault/Tamper Inquire [code] + [2] [1] + [#] √ √ √ √
Display all Event Log [code] + [2] [2] + [#] (only on text
keypad)
√ √
Display EN Event Log [code] + [2] [3] + [#] (only on text
keypad)
√ √
Display Dialer Event Log [code] + [2] [4] + [#] (only on text
keypad)
√ √
Bypass/Unbypass Zone [code] + [3] [1] + [#] + [2-digit zone no.] +
[#]
√ √ √ √ √
[code] + [3] [1] + [#] (cancel LED keypad) √ √ √ √ √
Bypass Fault/Tamper [code] + [3] [4] + [#] √ √ √ √
50 en | Settings AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH