Depending on the type of the output event, the output parameters can be defined as area
output or follow zone alarm output. The output polarity of each output can be programmed
and defined as one of the following modes: continuous output, pulse output or inverted
output.
The maximum output time is specified by programming and will automatically be reset after
expiration.
Output Events - Overview
Output event
type
Description Output area / zone
00 Not Used No
01 System Disarmed 0 = All areas
1 – 16 = areas 1 – 16*
02 System Armed
03 System Alarm 0 = Any area
1 – 16 = areas 1 – 16*
04 System Alarm (audible and silent)
05 External AWAY Siren
06 External STAY Siren
07 Internal Siren
08 Internal Siren with Tamper
09 Entry / Exit delay Warning 1 – 16 = areas 1 – 16*
10 Telephone Line Fault
11 AC Power Supply Fault
12 Low Battery
13 Tamper 0 = Any area
1 – 16 = areas 1 – 16*
14 External Fault
15 All Faults
16 Fire Alarm 0 = Any area
1 – 16 = areas 1 – 16*
17 Fire Reset
18 AWAY Armed 0 = All areas
1 – 16 = areas 1 – 16*
19 STAY Armed
20 Reset 0 = Any area
1 – 16 = areas 1 – 16*
21 Follow Zone Event Zone Number Zone number 1 – 64*
22 RF Keyfob Button 3 (e.g. garage
door)
0 = Any area
1 – 16 = areas 1 – 16*
23 RF Keyfob Button 4 (e.g. light)
24 Chime Indication
76 en | Settings AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH