Arm/Disarm Installer
Option Address Default
Arm/disarm installer (0 = disabled, 1 = enabled) 1602 0
Macro Programming
Macro Configuration
Macro no. Option Address Default
1 Macro without code (quick play macro) (0 =
disabled, 1 = enabled)
1611 0
Macro recording timeout (seconds) 1617 – 1618 60
Macro play pause time (unit: x100ms) 1619 – 1620 03
Code inside macro* (0 = disabled, 1 = enabled) 1621 1
Macro data length** 1622 – 1624 00
2 Macro without code (quick play macro) 1625 0
Macro recording timeout 1626 – 1627 60
Macro play pause time 1628 – 1629 03
Code inside macro* 1630 1
Macro data length** 1631 – 1633 00
3 Macro without code (quick play macro) 1634 0
Macro recording timeout 1635 – 1636 60
Macro play pause time 1637 – 1638 03
Code inside macro* 1639 1
Macro data length** 1640 – 1642 00
* This function is relevant only if the macro without code function is disabled.
** This function can not be changed via the programming menu, only via address
programming.
9.2.5