7 p q r s t u v w x y z { | } ~
8 đ Ą ᶏ Ł Ğ .. Ć Ś Ű Ş İ Ź Ę ź Ż
9 Ń ń Č ł ǧ ¨ ć ś ű č ş I Ț ę ţ ż
10 á ɨ ¢ £ € ¥ Š § š © ª « ¬ ־ ® ¯
11 ° ± ² ³ Ž µ ¶ • ž ¹ ° » Œ œ Ÿ ¿
12 À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï
13 Đ Ñ Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß
14 à á â ã ä å æ ç è é ê ë ì í î ï
15 ð ñ ò ó ô ô ö ÷ ø ù ú û ü ý þ ÿ
Table 9.2: Characters
System Factory Default Programming
Factory Default Pads Enable
Option Address Default
Factory default pads (0 = disable, 1 = enabled) 1604 1
Output and Siren Programming
Output Programming
Output no. Available for module Available on panel
01 - 03 On-board output AMAX 2100/3000/4000
04 On-board output AMAX 4000
05 – 12 DX3010 module 1 output AMAX 2100/3000/4000
13 - 20 DX3010 module 2 output AMAX 3000/4000
Output no. Option Address Default
01 Selecting the output event (00-36)* 0625 – 0626 05
Output parameter (area/zone no.) 0627 – 0628 00
Output pulse (0 = continuous, 1 = pulse, 3 =
continuous inverted)
0629 0
Output time (seconds) 0630 – 0632 180
02 Selecting the output event* 0633 – 0634 05
Output parameter 0635 – 0636 00
Output pulse 0637 0
9.5.2
9.6
9.6.1
132 en | Address Programming AMAX 2100 / 3000 / 4000
2014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH