Siren Programming
Option Address Default
Beep for warning devices (0 = disabled, 1 = enabled) 1600 1
Internal siren beep as indication (0 = disabled, 1 =
enabled)
1611 0
Silence warning device when disarmed (0 = disabled, 1 =
enabled)
1605 1
RF Device Programming
RF Options
Option Address Default
Printer functionality (0 = disabled, 1= enabled) 0991 0
RF receiver functionality (0 = disabled, 1= enabled) 0948 0
RF supervision interval (0 = disabled, 1 = 20 min, 2 = 1h, 3
= 2h, 4 = 4h, 5 = 12 h, 6 = 24h)
0949 4
EN=2
RF jam detect level (0 - 15, 0 = most sensitive) 0950 12
RF device low level battery resound (0 = disabled, 1 = 4h,
2 = 24h)
0951 2
Siren beep arm/disarm (RF keyfob) (0 = disabled, 1=
enabled)
0952 1
Keyfob panic option (0 = no alarm, 1 = silent alarm, 2 =
sound alarm)
0953 0
RF missing as alarm (0 = disabled, 1= enabled) 0954 1
Wireless Zone RFID
RFID for
wireless
zone no.
Address Default
(ten
digits, 15
= not in
use)
RFID for
wireless
zone no
Address Default
(ten
digits, 15
= not in
use)
1 5256 – 5265 15 33 5576 – 5585 15
2 5266 – 5275 15 34 5586 – 5595 15
3 5276 – 5285 15 35 5596 – 5605 15
4 5286 – 5295 15 36 5606 – 5615 15
5 5296 – 5305 15 37 5616 – 5625 15
6 5306 – 5315 15 38 5626 – 5635 15
9.6.2
9.7
134 en | Address Programming AMAX 2100 / 3000 / 4000