When the report is transmitted with Conettix IP Communication, some reports might be
missed. It is recommended not to separately use the ITS-DX4020-G module. If the ITS-DX4020-
G module is used, other network modules (e.g. B426) or the public telephone network can be
set as backup channel to ensure that no reports are missed.
The communication path of B426 / ITS-DX4020-G is as follows:
Module Address Setting Corresponding
Communication Path
Module 1: B426 module 1 / ITS-
DX4020-G
134 Paths 1 and 2
Module 2: B426 module 2 250 Paths 3 and 4
Only when IP module 1 is used and set to paths 1 to 4, the report can be sent to those paths.
Remote Access
The AMAX panel supports remote programming via USB, telephone, or IP network using the
software A-Link Plus. The following option can be performed:
– Setting the date and time
– Uploading / downloading programming parameters
– Remote arming / disarming of each area
– Enabling / disabling the alarm siren of each area
– Enabling / disabling each output
Remote Access Armed
– This option enables / disables the remote access for the function alarm.
Remote programming
– This option enables / disables the remote access for programming. If this function is
disabled, the system can not be programmed via an IP network anymore.
Remote PC
IP Address
RPC IP address is a fixed IP address for remote programming software.
Port Number
RPC port number is the port number for remote programming.
DHCP Update / RPC poll Time Interval
DHCP update / RPC poll time is the interval at which AMAX panel connects to the RPC
(Remote Programming PC).
The AMAX panel send UDP data packets to the RPC according to the DHCP Update Time
Interval setting (0=disabled 1-15h Interval), when the panel is reset and when call back is
finished.
RPC gets the Subscriber ID, IP address and port from the UDP data packets (IP No. and Port
is parsed from UDP data packet).
RPC with running RPS (Remote Programming Software = A-Link Plus) saves the received UDP
data packet information into its own RAM, the information is lost after RPS is closed.
7.1.5
7.1.6
AMAX 2100 / 3000 / 4000 Settings | en 43
Bosch Sicherheitsysteme GmbH Installation Guide 2014.11 | 02 | F.01U.267.112