Notice!
If the default pads are short-circuited for over 10 seconds after power-up, the AMAX panel
discards resetting to factory default.
Outputs and Sirens
Outputs
Onboard / Extension Output
The AMAX panel is equipped with on-board outputs and supports DX3010 output extension
modules with each extension module supporting 8 relay outputs.
When on-board output 1 or 2 fails due to a short circuit or an open circuit, as long as there is a
backup power supply, the output fault will not affect the normal operation of the whole
system, but will be detected by the system.
Each output is programmable and can be set to follow multiple events.
Depending on the type of the output event, the output parameters can be defined as area
output or follow zone alarm output. The output polarity of each output can be programmed
and defined as one of the following modes: continuous output, pulse output or inverted
output.
The maximum output time is specified by programming and will automatically be reset after
expiration.
Output Events - Overview
Output event
type
Description Output area / zone
00 Not Used No
01 System Disarmed 0 = All areas
1 – 16 = areas 1 – 16*
02 System Armed
03 System Alarm 0 = Any area
1 – 16 = areas 1 – 16*
04 System Alarm (audible and silent)
05 External AWAY Siren
06 External STAY Siren
07 Internal Siren
08 Internal Siren with Tamper
09 Entry / Exit delay Warning 1 – 16 = areas 1 – 16*
10 Telephone Line Fault
11 AC Power Supply Fault
12 Low Battery
13 Tamper 0 = Any area
1 – 16 = areas 1 – 16*
14 External Fault