LED/LCD Keypad Programming
An LED/LCD keypad can be used to program the system but only works with address
programming (please refer to Address Programming, page 105) as the programming menu can
not be displayed on the LED/LCD keypad. Therefore it is recommended to use a text keypad
or the PC software A-Link Plus for programming the system.
Access to the Menus
Accessing the Programming Menu
1. Confirm that the system is disarmed.
2. Enter the installer code. The default setting for the installer code is 1234.
3. Enter [958] + press the [#] key.
P The STAY and AWAY indicators flash to indicate the programming mode.
Accessing the User Menu
4 Enter the user code. The default setting for the user code is 2580.
P You have now access to the user menu for operating the AMAX system.
Navigation of the Menus
This section gives an overview of how to navigate while programming with a LED/LCD keypad.
Programming an Option
1. Enter the required address and enter the desired data value.
2. Press [*] to confirm.
3. Press [#] to exit.
4. Repeat step 1 if you want to program multiple options.
Exiting the Programming Mode
4 Complete all programming input by repeating the programming steps above and press
[–].
It is optional to save or not to save the programming data.
1. Enter [960] and press [#] to save the data and to exit the programming mode.
2. Enter [959] and press [#] to exit programming mode without saving the data.
For LED/LCD keypads, the programming data is displayed by the number indicators, as
described in the graphic below.
Programming Data Indicators
Data
Zone Indicators
Value 1 2 3 4 5 6 7 8 Mains
0
1 X
2 X
3 X
4 X
5 X
6 X
7 X
8.1.2
92 en | Configuration AMAX 2100 / 3000 / 4000
2014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH