Aux 1 / 2 (+12V/
GND) Output:
– Nominal Output Voltage under AC line input: 13,8 VDC +3% / -5%
– Vpp (max) 675mV
– Output Voltage Range under AC line
input: 12.82 VDC to 13.9 VDC
– max 500mA
– Output Voltage Range
under AC line input:
13.11 VDC to 14.2 VDC
– max 900mA
Option Bus:
Cable
requirements for
busses:
four wire, 0,6 to 1,2 mm Ø
max length 200m (Panel to last KP)
max bus length 700m (max 14 devices, max 8 KPs)
Option busses
common data:
– Nominal Output Voltage under AC line input: 13,8 VDC +3% / -5%
– Output Voltage Range under AC line input: 13.11 VDC to 14.2 VDC
Option Bus 1: max 500mA max 900mA
Option Bus 2: max 900mA
Panel PCB: Quiescent current max 100mA Quiescent current max
100mA
Battery: 12V/7 Ah, lead acid rechargeable
18Ah
Low battery condition is below 11,0 VDC
Minimum battery condition is 10,8VDC
Certification: Europe CE EN 50130-4 (6/2011)
EN 55022 (5/2008)
EN 60950-1:2006 + A11:2009
EN EN 50131-3 grade 2
Environmental Class 2
France AFNOR NF a2P 1223400001A0
Environmental Class 1
Germany VDS Home
Keypads:
IUI-AMAX4-TEXT (LCD Text Keypad)
Relative Humidity: 10% - 95%
Operating
Temperature:
-10°C - +55°C
Input Voltage
range:
10.8VDC - 13.8VDC
Current
Consumption:
standby 31mA
max 100mA
Ingress protection
rating:
IP 30
Security level: IK 06
AMAX 2100 / 3000 / 4000 Technical Data | en 33
Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297