Figure 5.11: Address and Key Programming
Setting date and time
After the system is powered up, date and time must be set. Otherwise, the system displays a
fault.
1. Make sure that the system is in a disarmed status (the STAY and AWAY indicators are
disabled).
2. Enter the installer code [1234] + [51] and press [*] to get to CHANGE DATE / TIME.
3. Enter the current date and time by using the numeric keys and press [–] to save the data
end exit the programming mode
P Date and time are set.
Deleting a Zone
The zones 1-8 are enabled by default. The zone type for zone 1 is set as 03-delay 1, for zones
2-8 as 01-instant by default. Perform the following steps if you want to delete a zone.
1. Enter the installer code [1234] + [958] and press [#].
2. Select 3 ZONE MANAGER and press [#].
3. Select ADD/DELETE ZONES and press [#].
The system displays the next menu item: INPUT ZONE No.
4. Enter the number of the zone you want to delete (example: 1) and press [#].
The system displays the next menu item: ZONE MODULE SEL.
5. Select the correct zone module (default is 0-on board zone) and press [#].
The system displays the next menu item: ZONE FUNCTION.
5.4.2
5.4.3
AMAX panel Programming and operating the AMAX panel | en 21