Zone tamper bypass when DEOL zone is bypassed (0 =
disabled, 1 = enabled)
1603 1
Tamper debounce time (unit: x100s) 1675 – 1678 0003
Area and Company Name Programming
Option Address Default
Area 1 name 2596 – 2615 0
Area 2 name 2616 – 2635 0
Area 3 name 2636 – 2655 0
Area 4 name 2656 – 2675 0
Area 5 name 2676 – 2695 0
Area 6 name 2696 – 2715 0
Area 7 name 2716 – 2735 0
Area 8 name 2736 – 2755 0
Area 9 name 2756 – 2775 0
Area 10 name 2776 – 2795 0
Area 11 name 2796 – 2815 0
Area 12 name 2816 – 2835 0
Area 13 name 2836 – 2855 0
Area 14 name 2856 – 2875 0
Area 15 name 2876 – 2895 0
Area 16 name 2896 – 2915 0
Company Name 2916 – 2951 0
An area or company name may have up to 18 characters. Each character of the area or
company name uses 2 addresses.
How to insert alphabetical characters via address programming
– A character needs two values to provide input to two addresses.
– Determine these values using the matrix of table below.
– Every character in this table has a row index and also a column index.
– Row index is the first, and column index is the second value for each character.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2 ! " # $ % & ' ( ) * + - , . /
3 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4 @ A B C D E F G H I J K L M N O
5 P Q R S T U V W X Y Z [ \ ] ^ _
6 ‛ a b c d e f g h i j k l m n o
136 en | Address Programming AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH