25 Verified Alarm
26 Unverified Alarm
27 Technical Alarm
28 Bypassed Zone
29 Ready to Arm 0 = All areas 1 – 16 = Areas 1 – 16*
30 Walk Test Output Mode
31 24h Alarm 0 = Any area
1 – 16 = areas 1 – 16
32 24h Panic Alarm
33 Medical Alarm
34 RF Power Fault 0 = Any repeater
35 Follow Zone 0 = Any area
1 – 16 = areas 1 – 16
36 Schedule
Table 6.1: The value ranges of output event options
* AMAX 2100 areas 1 - 2 zones 1 - 8
AMAX 3000 / 3000 BE areas 1 - 8 zones 1 - 32
AMAX 4000 areas 1 - 16 zones 1 - 64
Output Events – Detailed description
00 - Not Used
01 – System Disarmed
The output is operated in the following cases:
The system is disarmed after a system reset.
The system operated the disarm command.
The output is reset in the following cases:
The system is armed.
The programmed output time ends.
02 - System Armed
The output is operated in the following cases:
The system is armed after a system reset.
The system operated the arm command. (After the exit time ends.)
The output is reset in the following cases:
The system is disarmed.
The programmed output time ends.
If the output time is set to 000, the output will continue until the system is disarmed.
03 - System Alarm
This output is operated when an alarm occurs.
The output is reset in the following cases:
The system is disarmed and alarm is reset.
AMAX panel
Settings | en 77
Bosch Sicherheitssysteme GmbH Installation Manual 2015.05 | 06 | F.01U.309.277