Function Command
Default code for user 1 =
2580
Default code for user 2 =
2581
D A B S M
2
M
1
I
N
Bypass/Unbypass
Zone
Text keypad: [code] + [3]
[1] + [#] + [1 or 2-digit
zone no.] + [#]
LED/LCD keypad: [code] +
[3] [1] + [1 or 2-digit zone
no.] + [*] + [#]
√ √ √ √ √
[code] + [3] [1] + [#]
(cancel LED keypad)
√ √ √ √ √
Bypass Fault/
Tamper
[code] + [3] [4] + [#] √ √ √ √
Inquire Bypass [code] + [3] [3] + [#] √ √ √ √ √
Isolate/Unisolate
Zone
[code] + [3] [5] + [#] √ √ √
Inquire Isolate [code] + [3] [6] + [#] √ √ √
Reset
Reset Fault/
Tamper (In some
country versions
only the installer
can reset a
tamper alarm)
[code] + [6] + [#] √ √ √ √
Macros
Record Macro 1 [code] + [8] [1] + [#] +
sequence to be recorded +
[#] for 3 sec.
√ √ √ √