76 en | Technical Data AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12 Installation Manual Bosch Sicherheitssysteme GmbH
Aux (+12V/GND) Output: Nominal Output Voltage under AC line input: 13,5 VDC +3%
/ -5%
Output Voltage Range under AC line input: 12,82 VDC to
13,9 VDC
500mA maximum
Vpp (max) 675mV
Option Bus: Nominal Output Voltage under AC line input: 13,5 VDC +3%
/ -5%
Output Voltage Range under AC line input: 12,82 VDC to
13,9 VDC
500mA maximum
RF Power Output 5VDC / 100mA maximum
Panel PCB Quiescent current maximum 100mA
Battery: D126 (12V/7 Ah) sealed, lead acid rechargeable
Low battery condition is below 11,8 VDC
Minimum battery condition is 10,8VDC
Maximum auxiliary current to recharge standby battery to
80% within 72h: 12 V/7 Ah Battery: 550mA
Certification: EN 50131-3 GRADE 2 ENV-II = ENVIRONMENTAL GRADE II
Keypads:
IUI-AMAX-LED8 (8Zone LED Keypad)
Relative Humidity: 10%-95%
Operating Temperature: -10°C - +55°C
Input Voltage range: 10VDC - 14VDC
Current Consumption standby 24mA
maximum 50mA
Cable requirements: four wire, unshielded and shielded 0,6-0,8mm
maximum length 150m
EN type: B
IUI-AMAX-LCD8 (8Zone LCD Keypad)
Relative Humidity: 10%-95%
Operating Temperature: -10°C - +55°C
Input Voltage range: 10VDC - 14VDC
Current Consumption standby 18mA
maximum 60mA
Cable requirements: four wire, unshielded and shielded 0,6-0,8mm
maximum length 150m
EN type: B