84 en | Programming sheets AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12 Installation Manual Bosch Sicherheitssysteme GmbH
Zone Types
Silent Alarm (Enable=1, Disable=0) 263
0
EN=0
Zone alarm lock out time (disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=4)
264 0
Support Detector Tamper (Disable=0, Enable=1) 265 1
Zone alarm report (Refer to zone report option) 266
6
EN=1/5/
6/7
Zone Chime Mode (Enable=1, Disable=0) 267 0
Reserved 268-269 0
Zone #07
Zone Type (Refer to zone type option) 270 1
Zone Bypass (Disable=0, Enable=1) 271 1
Forced Arming (Disable=0, Eanble=1) 272
1
EN=0
Silent Alarm (Enable=1, Disable=0) 273
0
EN=0
Zone alarm lock out time (disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=4)
274 0
Support Detector Tamper (Disable=0, Enable=1) 275 1
Zone alarm report(Refer to zone report option) 276
6
EN=1/5/
6/7
Zone Chime Mode (Enable=1, Disable=0) 277 0
Reserved 278-279 0
Zone #08
Zone Type (Refer to zone type option) 280 1
Zone Bypass (Disable=0, Enable=1) 281 1
Forced Arming (Disable=0, Enable=1) 282
1
EN=0
Silent Alarm (Enable=1, Disable=0) 283
0
EN=0
Zone alarm lock out time (Disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=4)
284 0
Support Detector Tamper (Disable=0, Enable=1) 285 1
Zone alarm report(Refer to zone report option) 286
6
EN=1/5/
6/7
Zone Chime Mode (Enable=1, Disable=0) 287 0
Reserved 288-289 0
Zone Type Description
0 Zone not used
1 Instant
2 Interior Instant
3Delay
4Interior Delay
5 Follower
6 Interior Follower