AMAX panel 2000 / AMAX panel 2000 EN Programming sheets | en 85
Bosch Sicherheitssysteme GmbH Installation Manual F.01U.241.127 | V4 | 2011.12
10.5 Output Programming
10.5.1 Keypad Buzzer
10.5.2 Warning Device 1 / OC1 Output
10.5.3 Warning Device 2 / OC2 Output
10.5.4 Optional Relay Output / OC3
10.5.5 DX3010 Output
7 24-Hour
8Tamper
9Fire
10 External Fault
11 Bolt Contact
12 Key Switch Toggle
13 Key Switch on/off
Zone Type Description
Location 370 Location Default
Keypad beeps when siren on 1=Disable, 1=Enable 370 0
Output 1 Location Default
Event type (fixed value)
3
EN
Polarity Mode (0=Steady, 1=Pulse) 371
0
EN=0
Output Duration (001-999sec/000=on) 372-374 000
EN=180
NOTICE!
When the triggered zone is programmed as silent zone, keypad output and OC1 output do not
response. Other outputs are as normal.
Output 2 Location Default
Event type (Refer to output events option) 375
3
EN=3
Polarity Mode (0=Steady, 1=Pulse) 376
0
EN=0
Output Duration (001-999sec/000=on) 377-379 000
EN=180
Optional Relay Output
Event Type (Refer to output events option) 380 0
Polarity Mode (0=Steady, 1=Pulse) 381 0
Output Duration (001-999sec/000=on) 382-384 030
Location Location Default
Relay Output 1
Event Type (Refer to output events option) 385 0