Notice!
The maximum number of keypads to be added to one option bus is 8.
Status Indicator
If all indicators of the keypad are flashing, the keypad loses connection to the AMAX panel.
DX2010
General
The AMAX panel supports DX2010 input expansion modules. Each expansion module supports
up to 8 zone inputs.
For information on the installation, refer to Module Installation, page 26.
Address Setting
Each DX2010 module connected to the AMAX panel needs its own data bus address.
Data Bus Address Zones
102*** 9 - 16
103** 17 - 24
104** 25 - 32
105* 33 - 40
106* 41 - 48
107* 49 - 56
108* 57 - 64
Table 4.4: DX2010 Address Settings
DIP Switch
S1 S2 S3 S4 S5 S6
Data Bus Address 32 16 8 4 2 1
102*** Off Off Off Off Off On
103** Off Off Off Off On Off
104** Off Off Off Off On On
105* Off Off Off On Off Off
106* Off Off Off On Off On
107* Off Off Off On On Off
108* Off Off Off On On On
Table 4.5: DX2010 DIP Switch Settings
* AMAX 3000 BE / 4000
4.2.4
4.3
4.3.1
4.3.2
16 en | Optional Modules and Peripheral Devices AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH