Stable flash Normal Operation
Off Power failure
DX3010
General
The AMAX panel supports DX3010 output expansion modules. Each module supports 8 fully
programmable relay outputs.
For information on the installation, refer to Module Installation, page 26.
Address Setting
Each DX3010 module connected to the AMAX panel needs its own data bus address.
Data Bus Address Outputs
150 5-12
151* 13-20
Table 4.7: DX3010 Address Settings
DIP Switch S1 S2 S3 S4 S5 S6
Data Bus Address 1 2 4 8 16 Mode
150 On On On On On Off
151* Off On On On On Off
Table 4.8: DX3010 DIP Switch Settings
* AMAX 3000 / 3000 BE / 4000
Figure 4.5: DX3010 DIP Switch Settings
Wiring
The following table and graphic show how to wire DX3010 to the option bus of the AMAX
panel.
Power Supply Wire diameter of 0.8mm Wire diameter of 1.2mm
AMAX panel 12.2m 24.4m
External power supply 305m 610m
Table 4.9: Lengths of cable for DX3010
4.4
4.4.1
4.4.2
4.4.3
18 en | Optional Modules and Peripheral Devices AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH