Keypad Indicators
The following table shows an overview and a description of the
keypad indicator icons.
Keypad
Indicator
Icons
Status Definition
1 2 3 ….
ZONE (1-8)
on Zone is triggered.
off Zone is normal.
Fast flash (0.25
seconds lights on/0.25
seconds lights off)
Zone was alarmed or is
in alarm status.
Slow flash (1 second
lights on/1 second
lights off)
Zone is manually
bypassed or interior
Zone is in STAY arm
mode.
AWAY
on System is armed in
AWAY mode.
off System not armed in
AWAY mode.
Slow flash (1 second
lights on/1 second
lights off)
Exit time.
Fast flash (0.25
seconds lights on/0.25
seconds lights off)
Programming mode or
code function mode.
STAY indicator flashes
simultaneously.
on System is armed in
STAY mode.
2.3