EasyManuals Logo

Bosch B4512 Installation Manual

Bosch B4512
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Control Panels Appendix | en 137
Bosch Security Systems, Inc. Installation Manual 2018.07 | 16 | F.01U.287.180
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Invalid Popit Address Restore Rpppp NriaaBRpppp Loss of Supervision - RPM
Restore
3 382 aa ppp
IP Address Error TsssD NpiddddET System Peripheral Trouble 1 330 00
1
zzz
IP Address Error RsssD NpiddddER System Peripheral Trouble
Restore
3 330 00
1
zzz
Key fob Missing VsD10 NidiiiiUY Latch-Key Supervision 1 642 00 iii
Key fob Missing Restoral RsD10 NidiiiiUR Latch-Key Supervision
Rest.
3 642 00 iii
Key fob Panic Assss NidiiiiPA Duress Alarm 1 121 00 iii
Key fob Silent (Hold Up)
Alarm
Dssss NidiiiiHA Duress Alarm 1 121 00 iii
Keypad Panic Alarm Apppp Nriaa/Papppp Panic Alarm 1 120 aa ppp
Keypad Silent (Hold-Up)
Alarm
Dpppp Nriaa/Happpp Silent Alarm 1 122 aa ppp
Medical Alarm Apppp Nriaa/Mapppp Personal Emergency 1 101 aa ppp
Missing Alarm Mpppp NriaaUZpppp General Alarm 1 140 aa ppp
Missing Fire Supervision GMpppp NriaaFZpppp Fire Trouble 1 373 aa ppp
Missing Gas Supervision Vpppp NriaaGSpppp Sensor Trouble 1 380 aa ppp
Missing Supervision MTpppp NriaaBZpppp Loss of Supervision -RPM 1 382 aa ppp
Missing Trouble Vpppp NriaaUYpppp Loss of Supervision - RPM 1 382 aa ppp
Network Cable Connected NsD43 NpiddddNR010 System Peripheral Trouble
Restore
3 330 00 zzz
Network Cable Disconnected NsD42 NpiddddNT010 System Peripheral Trouble 1 330 00 zzz
Non-Fire Cancel Alarm \siiii Nriaa/idiiiiBC Cancel 1 406 aa uuu
Normal start-up of the control
panel
NsD14 NRR System Reset 1 305 00 000
Opening by Account Osiiii NidiiiiOP O/C by account 1 401 00 uuu
Opening by Area Osiiii Nriaa/idiiiiOP O/C by user 1 401 aa uuu
Opening Early by Area Osiiii Nriaa/idiiiiOK Early O/C 1 451 aa uuu
Opening Late by Area Osiiii Nriaa/idiiiiOJ Late O/C 1 452 aa uuu
Parameters changed NsD02 NYG Panel Programming
Changed
1 306 00 000
Personal Notification
Communication Trouble
TsB01 NpiddddYS Communication Trouble 1 350 0 zzz

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories