Control Panels Keypad Installer menu | en 135
Bosch Security Systems, Inc. Installation Manual 2018.07 | 10 | F.01U.303.996
2. Go to [1] Programming Menu > [1] Reporting > [4] Personal Note. The keypad shows
the phone number or email address of the selected personal notification destination.
3. Use /Previous or /Next to scroll through the list of destinations and go to the
destination you want to program.
4. Press Edit or Enter to edit the phone number or email address.
5. Delete existing characters, if necessary, and then enter the new characters.
6. Press Save or Enter. The keypad shows Parameter saved.
20.1.5 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1]
Module Parameters menu
You can use DCHP/AutoIP or UPnP for Ethernet communication with the on-board Ethernet or
a B426. In this menu, you can enable and disable these protocols.
Default Module settings
DHCP/AutoIP Enable Yes Yes/No
UPnP Enable Yes Yes/No
IPv4 Address 0.0.0.0 _______________________________
IPv4 Subnet Mask 255.255.255.255 _______________________________
Default Gateway 0.0.0.0 _______________________________
HTTP Port Number 80 _______________________________
IPv4 Server Address 0.0.0.0 _______________________________
IPv6 Server Address 0.0.0.0 _______________________________
Module Hostname Blank _______________________________
DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [1] Module Parameters > [1] DHCP Enable. The keypad shows the DHCP/
AutoIP current configuration.
3. Depending on the keypad model:
Press Yes or No.
-or-
Press Enter to edit the DHCP/AutoIP Enable configuration for the module. Use Previous
or Next to toggle between Yes and No..
4. Press Save or Enter. The keypad shows Parameter saved.
5. Escape from the menu.
UPnP Enable
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [1] Module Parameters > [2] UPnP Enable. The keypad shows the UPnP
current configuration.
3. Depending on the keypad model:
Press Yes or No.
-or-