148 en | Keypad Installer menu Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
Point Indexes (point profiles) 26 through 63
Point Index Text defaults (the second language text defaults are blank):
Point Index 25 Part On: Delay Watch Off
Point Index 26 Part On: Instant (2)
Point Index 27 Part On: Delay (2)
Point Index 28 Interior: Follower (2)
Point Index 29 Interior: Instant (2)
Point Index 30 Interior: Delay (2)
Point Index 31 24-hr Inst. Open/Short, no Abort
Point Index 32 Run Custom Function
Point Indexes 33-63
(B9512G only)
Index [33 to 63]
Point Index # 25 26 27 28 29 30 31* 32
Point Index Text
(1st language)
Part On:
Delay W
Part On:
Inst (2)
Part On:
Delay (2)
Interior:
Fllwr (2)
Interior:
Inst (2)
Interior:
Delay (2)
24-hr
Inst. Op
Run
Custom
Point Index Text
(2nd language)
(blank) (blank) (blank) (blank) (blank) (blank) (blank) (blank)
Point Type / Response /
Circuit Style
Part On Part On Part On Interior
Follower
Interior Interior 24-Hour 24-Hour
Point Response __(4)__ __(0)__ __(0)__ __(0)__ __(0)__ __(0)__ __(0)__ __(0)__
Entry Delay _(30)__ _(30)__ _(30)__ _(30)__ _(30)__ _(30)__ _(30)__ _(30)__
Entry Tone Off Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Silent Bell Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Ring Until Restored Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Audible After Two Fails Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Invisible Point Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Buzz on Fault ______ ______ ______ ______ ______ ______ ______ ______
Watch Point Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Output Response Type ______ ______ ______ ______ ______ ______ ______ ______
Display as Device Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Local While Disarmed Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Local While Armed Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Disable Restorals Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
FA Returnable Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N
Bypass Returnable Y/N Y/N Y/N Y/N Y/N Y/N Y/N Y/N