176 en | Appendix Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Configuration Failure
Restoral (Device)
RssssD NpiddddER System Peripheral Trouble
Restoral
3 330 00 zzz
Control panel battery low Tsss9 NYT Low System Battery 1 302 00 000
Control panel battery missing Tsss9 NYM Battery Missing/Dead 1 311 00 000
Control panel battery
restored to normal
Rsss9 NYR Low System Battery
Restore
3 302 00 000
Control panel off-line TsssF Nid5002TS System Shutdown 1 308 00 F02
Control panel on-line RsssF Nid5002TE System Shutdown Restore 3 308 00 F02
Create Status Report Sssss NYY Status Report to Follow 1 605 00 000
Date changed – no user
indentified
NsD07 NJD Time/Date Reset 1 625 00 000
Date changed by user NsD07 NidiiiiJD Time/Date Reset 1 625 00 uuu
Delete User by User NsD05 NidiiiiJXiiii Local Only Local Only
DNS Failure TsB01 NpiddddYS Communication Trouble 1 350 00
1
zzz
DNS Failure Restore NsB01 NpiddddYK Communication Trouble
Restore
3 350 00
1
zzz
Duplicate SDI2 device TsssD NpiddddET System Peripheral Trouble 1 330 aa iii
Duplicate SDI2 device
Restore
RsssD NpiddddER System Peripheral Trouble
Restore
3 330 aa iii
Duress Diiii Nriaa/idiiiiHA Duress 1 121 aa uuu
Equipment Fail TsD29 NpiddddIA System Peripheral Trouble 1 330 00
1
zzz
Equipment Restore RsD29 NpiddddIR System Peripheral Trouble
Restore
3 330 00
1
zzz
Event Log Overflow AsD01 NJO Event Log Overflow 1 624 00 000
Event Log Threshold has
been reached
TsD01 NJL Event Log 90% Full 1 623 00 000
Extend Close Time by Area TsD26 Nriaa/idiiii/
tihhmmCE
Auto-arm Time Extended 1 464 aa uuu
Extra Point Tpppp NriaaXEpppp Maintenance Alert 1 393 aa ppp
Fail To Close by Area TsssE NriaCl Failed to Close 1 454 aa 000
Fail to Open by Area TsssE NriaOl Failed to Open 1 453 aa 000
Fire Alarm Fspppp NriaaFApppp Fire 1 110 aa ppp
Fire Cancel \iiii Nriaa/idiiiiFC Cancel 1 406 aa uuu
Fire Drill Start TsssF Nriaa/idiiiiFL Fire Test Start 1 604 aa iii
Fire Drill End RsssF Nriaa/idiiiiNF Fire Test End 3 604 aa iii

Table of Contents