278 en | Hardware switch settings Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
Serial
device
Door controller address Fail Mode
Keypad
display
Central
Station
Modem
IIIIa
2
1 2 3 4 5* 6*
D9210 #5 SDI #37 ON ON OFF -- -- --
D9210 #6 SDI #38 OFF ON OFF -- -- --
D9210 #7 SDI #39 ON OFF OFF -- -- --
D9210 #8 SDI #40 -- -- -- -- -- --
SDI Fail Mode
SDI Fail –
Door Unlocked
-- -- -- ON -- --
SDI Fail –
Door Locked
-- -- -- OFF -- --
* DIP switches 5 and 6 must stay in the ON position.
To enable SDI Fail Mode, set DIP switch 4 to ON.
To disable SDI Fail Mode, set DIP switch 4 to OFF.
D9210C
Fail mode Central station
Modem4
SDI address setting Keypad display
UNLOCKED SDI #33 81 Door #1
UNLOCKED SDI #34 82 Door #2
UNLOCKED SDI #35 83 Door #3
UNLOCKED SDI #36 84 Door #4
UNLOCKED SDI #37 85 Door #5
UNLOCKED SDI #38 86 Door #6
UNLOCKED SDI #39 87 Door #7
UNLOCKED SDI #40 88 Door #8
LOCKED SDI #33 91 Door #1
LOCKED SDI #34 92 Door #2
LOCKED SDI #35 93 Door #3
LOCKED SDI #36 94 Door #4
LOCKED SDI #37 95 Door #5
LOCKED SDI #38 96 Door #6
LOCKED SDI #39 97 Door #7