180 en | Appendix Control Panels
2018.07 | 10 | F.01U.303.996 Installation Manual Bosch Security Systems, Inc.
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Time Changed - No User
Identified
NsD07 NJT Time/Date Reset 1 625 00 000
Time Changed by Receiver
Sync
NsD07 Nid5001JT Time/Date Reset 1 625 00 F01
Time Changed by User NsD07 NidiiiiJT Time/Date Reset 1 625 00 uuu
Trouble Tspppp NriaaBTpppp Sensor Trouble 1 380 aa ppp
Unverified Event Kpppp NriaaUGpppp Cross-Zone Trouble 1 378 aa ppp
User Authority level has
changed
NsD40 NidiiiiJZiiii Local Only Local Only
User Passcode Tamper - Too
Many Attempts
NsD03 NriaJA Wrong Code Entry 1 461 aa 000
Walk Test End RsssF Nriaa/idiiiiTE Walk Test Mode Emd 3 607 aa uuu
Walk Test Start TsssF Nriaa/idiiiiTS Walk Test Mode 1 607 aa uuu
Watchdog Reset NsD09 NpiddddYW System Reset 1 305 00 000
Watchdog Reset - SDI Device
Reported identifies the
Source
NsD09 NpiddddYW System Reset 1 305 00 000
1
zzz represents an SDI, or SDI2 device address value, or network trouble condition, indicated by a number (for
example, 501).
22.2.2 Device numbers (zzz, dddd)
Device number zzz data values Description
01-16 001-016 SDI Keypads 1-16
01-59 201-259 SDI2 Octo-Input Modules 1-59
01-59 301-359 SDI2 Octo-Output Modules 1-59
1 801 SDI2 Premises RF Module
N/A 851-858 RF Repeater 1-8
01-02 401-402 SDI2 Network Modules 1-2
01-08 501-508 SDI2 Power Supply Modules 1-8
01-32 901-932 SDI2 Keypads 1-32
01-06 155-160 SDI2 POPEX Modules 1-6
01-08 33-40 SDI Access Modules 1-8
01-32 601-632 SDI2 Access Modules 1-32
N/A 516-531 IP Cameras 1-16
OnBrd 100 Control Panel Enclosure