82 en | Off-board points Control Panels
2018.07 | 10 | F.01U.303.996 Installation Manual Bosch Security Systems, Inc.
Wiring the module to the control panel
Callout ᅳ Description
1 ᅳ ZONEX connection cable
2 ᅳ SDI interconnect cable
Wiring the terminal strip
Refer to the next section for information on how to wire the terminal strip.
13.3.2 D8125 expansion
The control panel supports up to two of the following modules (referred throughout this
section as “D8125”) through the use of the B600:
– D8125 Expansion Module
– D8125MUX Expansion module, Multiplex
– D8125INV Wireless Module
– D8125CW-V2 Interface module, Inovonics Echostream
Calculate power consumption
Make sure that there is enough power for the module and the other powered devices that you
want to connect to the system.
Refer to On-board outputs, page 65.
Caution!
Remove all power (AC and battery) before making any connections. Failure to do so might
result in personal injury and/or equipment damage.