System Modes
Unit Operating Mode
Heat: Unit will be cycled to maintain scheduled heating set-point.
Cool Only: Unit will be cycled to maintain scheduled cooling set-point.
Auto: Unit will be automatically switched between heating and
cooling operations to maintain heat/cool set-points.
Off: All heating and cooling functions are turned off. Fan can still
operate in this mode if manually activated.
Emergency Heat (only available on Heat Pumps):
Will turn off all compressors and turn on backup electric heat source.
Fan Operation
Auto: Fan will follow heating
and cooling operations.
On: Fan runs non-stop for 24 hours.
Circulation: Fan runs on and off
regularly in addition to heating and cooling operations.
By selecting this option, you also need to define the
operation time length and schedule for the circulation.
If the G wire was substituted for the C wire during
installation, the Fan-On & Circulation options will
not function.