Advanced Settings is designed for professionals who want
to utilize advanced features for better accessibility. It will
also allow the user to factory reset the device and
requires an access code.
AB: Auto-mode Switch Band*
Set difference for auto switch between heating/cooling
PM: Parameter Modifier*
Advanced settings for system key parameters
SC: Sensor Calibration*
To calibrate or correct the device temperature reading
SD: System Default*
Restore system to default setting
SI: System Information
Display hardware and software info for the device
SL: System Lock/Unlock
Lock the thermostat to prevent on-device operation
ZB: Zero Energy Band*
The temperature range where no heating or cooling is
activated during operation