7.7 Control board diagnostics
1. Press ON/OFF button into ON.
2. Press and hold simultaneously buttons or and for 3
seconds, until display reads P2.
3. Press to enter P2 adjustment. The current setting will appear on
the display. If not, repeat process.
4. Press and release the button on the control panel until the
display reads 'P4'. You are now in the diagnostic mode of the control
board.
5. When the display reads 'P4', press and release the button once
again and the display should read 'E'.
6. Use the and button on the control board to cycle through
different diagnostic modes available.
7. Once in the selected diagnostic mode of your choice, press and
release the button to display the diagnostic information.
EXAMPLE: to read the flow rate in gallons per minute while the unit is
flowing water, cycle to the '3d' mode and press the button. A
reading of 25 on the display would indicate the heater is reading a flow
rate of 2.5 gallons/minute.
8. Once the information is obtained, press the button again to
return to the diagnostic mode menu and scroll to addition diagnostic
information.
9. Press ON/OFF button to turn OFF the appliance and back ON again to
return heater to normal function.
Program Description Factory Default MIN MAX Comment
P0 Temperature range
settings
H: C 1210 ES
C: C 1210 ESC
- - This values are set from factory they cannot be
changed.
P1 Maximum Power NG: 52,
LP: 53
21 NG: 52,
LP: 53
see chapter 4.14, page 31
note: reducing P1 values below maximum will
reduce maximum power of the appliance.
P2 Minimum Power 12 12 20 see chapter 4.3.7, page 21
P3 Remote
Controls installed
_0 _0 6 see chapter 6.5, page 34
P4 Access to
Diagnostic Mode
E0d10F see chapter 7.7, page 39
P5 Cascade Mode NO NO CC contact Bosch for details
P6 Temperature Unit °F °F °C
P7 Gas type selection LP or NG Preset from factory.
Contact Bosch for details.
P8 Back light dE dE ON dE turns back light off after 60 seconds from last
button pushed, ON turns backlight on
permanently.
P9 Fan Purge Runs secondary fan and primary fan when P9 is
selected by depressing the “P” - button
PH Cascading type IC IC SC This menu is only available when cascade mode is
selected CC.
Contact Bosch Water Heating for details.
PC Primary/Secondary
mode
CS CS Cn
Table 34 Program values, factory default settings and ranges.
Diagnostic menu
E Entry/Exit into sub-modes
0d Heat exchanger water temperature
1d Inlet water temperature (°F)
2d Outlet water temperature (°F)
3d Water flow (gallons/min)
4d Bypass control monitor (°F) [0d - 2d]
5d Fan speed (Hz)
6d Burner power (%)
7d Maximum power (kW)
8d Back flow temperature (°C)
9d Exhaust temperature (°C)
1F Most recent error/failure
2F 2nd most recent error
3F 3rd most recent error
4F 4th most recent error
5F 5th most recent error
6F 6th most recent error
7F 7th most recent error
8F 8th most recent error
Table 35 * Settings define from factory