System components
7
Systemlösung – 6 720 885 509 (2018/03)
2.2.2 Technical data
Unit CHP CE 240
NE
CHP CE 400
NE
CHP CE 600
NE
CHP CE 800
NE
CHP CE 854
NE
CHP CE 1200
NE
GenSet
Gas category Natural gas Natural gas Natural gas Natural gas Natural gas Natural gas
Power
consumption
kW 668 1034 1438 1898 1993 2750
Electrical output kW 240 400 600 800 854 1200
Thermal output kW 236 288 333 431 443 625
Electrical
efficiency
% 35.9 38.7 41.7 42.1 42.8 43.6
Type Design
external flue
gas heat
utilisation
Design
external flue gas
heat utilisation
Design
external flue gas
heat utilisation
Design
external flue gas
heat utilisation
Design
external flue
gas heat
utilisation
Design
external flue
gas heat
utilisation
Engine
manufacturer
MAN MAN MWM MWM MTU MWM
Engine model E2842 E 312 E2842 LE 322 TCG 2016 V12 C TCG 2016 V16 C 8V4000 L33 TCG 2020 V12
Dimensions
Length mm 4380 5300 3900 4057 4200 3900
Width mm 1510 1660 2400 1467 2000 2400
Height mm 1980 2472 2260 2190 2300 2260
Weight (empty) kg 4400 6950 6670 7550 10000 11730
Generation of electricity
Generator
manufacturer
Leroy Somer Leroy Somer Marelli Marelli Stamford Marelli
Generator type LSA 47.2
M7/4P
LSA 47.2 M7/4P
LSA 49.1 S4/4P
MJB 400 LC4 MJB 450 MB4 PE734C MJB 500 MB4
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50
Speed 1/min 1500 1500 1500 1500 1500 1500
Efficiency of
generator
% 96.1 96.2 96.8 97.1 95.9 97.3
Temperature levels
LT mixture circuit °C 47.5/45 44/40 46/40 42/40 43/40
Heating water
without flue gas
heat exchanger
°C 83/70 82/72 85/75 85/75 85/75 85/75
Flue gas
temperature
without flue gas
heat exchanger
°C 570 440 453 452 443 414
Maximum flue gas
temperature
°C 650 650 550 550 550 550
Flue gas tube
dimension (KAT)
DN 200/PN 10 DN 200/PN 10 DN 250/PN 10 DN 300/PN 10 DN 300/PN 10 DN 350/PN 10
Flue gas mass flow
rate (wet)
kg/h 877 2102 3343 4418 4524 6551
Available flue gas
back pressure
mbar 15 17 25 25 25 25
Flue gas back
pressure boiler
mbar 10 10 15 15 15 15
Flue gas limit values
CO mg/m
3
i.N.
d300 d300 d300 d300 d300 d300
NOx mg/m
3
i.N.
d250 d500 d250 d250 d250 d250
NMHC mg/m
3
i.N.
d150 d150 d150 d150 d150 d150
Table 1 Specifications CHP CE 240 NE ... CHP CE 1200 NE