P/N: CM710BIRG Rev 1.3 Page 5
Copyright © 2012 E&OE
Output Event Types - Solution 144 and Solution E Panels
The table below list the various output event types which are available on the Solution 144 and Solution E control
panels. Refer to the full installation manual for more detail on the individual event types.
Output Event Type Table
00 - Disabled P 26 - Entry Timing A 52 - Exit Error A
01 - Battery Trouble P 27 - Exit Timing A 53 - Keyfob Function 1 A
02 - AC Trouble P 28 - End Of Exit Time A 54 - Keyfob Function 2 A
03 - Telco Line Fail P 29 - Chime On A 55 - Output In PreDelay Op
04 - Comm Fail Rr 30 - Chime Zone Faulted A 56 - Follow PIN Code Ur
05 - 3rd Dial Attempt Rr 31 - Auto Arm Pre Alert A 57 - Part Entry Time A
06 - Dest Reporting Rr 32 - Ready To Arm All On A 58 - TimeZone Tz
07 - Disabled 33 - Ready To Part Arm A 59 - Temperature Hi/Lo Kp
08 - Destination Kiss Off Rr 34 - Ready To Part 2 Arm A 60 - Door Dr
09 - Keyfob Function 1 Ur 35 - Close Sent OK A 61 - Door Open Too Long Dr
10 - Keyfob Function 2 Ur 36 - External Audible A 71 - CLI Trigger CLI
11 - Dialler Disabled P 37 - Internal Audible A 72 - GSM Signal Lost P
12 - Output Device Missing P 38 - Any Zone Alarm A 73 - GPRS Failure P
13 - Output Trouble Op 39 - Fire Alarm A 74 - Ethernet Fail P
14 - Panel On Line P 40 - Burglary Alarm A 75 - Macro Ma
15 - Incoming Call P 41 - Silent Alarm A
16 - System Trouble P 42 - Duress Alarm A
17 - Box Tamper Zn 43 - Keypad Medical A
18 - Zone Trouble Zn 44 - Keypad Fire A
19 - Zone Mirror Zn 45 - Keypad Panic A
20 - Zone Alarm A 46 - Device Tamper A
21 - Area Disarmed A 47 - Access Denied A
22 - Area Part Or All On A 48 - Strobe A
23 - Area All On A 49 - Smoke Sensor GND A
24 - Area Part On A 50 - Sensor Watch A
25 - Area Part 2 On A 51 - Senior Watch A
Legend:
(Ma) = Macro (P) = Panel Event Assignment (Ur) = User Event Assignment
(CLI) = CLI Trigger Table (Op) = Output Event Assignment (Tz) = Time Zone Event Assignment
(A) = Area Event Assignment (Zn) = Zone Event Assignment (Dr) = Door Group Event Assignment
(Kp) = Keypad (Rr) = Reporting Destination
Table 6: Output Event Types
i
Note
The event types available on the Solution 16i panel differ from those in
the above table. Please refer to the Solution 16i Quick Reference Guide
for detailed event type information.