6 720 801 244 (2013/08) Compress 3000 DW FO
28 | Operation Instructions
Fig. 27 „P2“ and „P3“ periods
Setting the operating periods to „P2“ and „P3“
4 operating periods will be set in each of the functions:
• 2 periods for days „1 to 5“
• 2 periods for days „6 to 7“
Definition of operating periods
▶ Access the „P2“ or „P3“ functions ( section 5.4).
▶Press „ok“.
Display shows the start schedule of the 1
st
operating
period in blink mode.
Fig. 28 Start of 1
st
operating period
▶ Use the „+“ and „-“ keys to define the operating start
schedule.
▶Press „ok“.
Blinking display shows operating stop schedule for the 1
st
period.
▶ Use the „+“ and „-“ keys to set the operating duration.
▶ Press „ok“.
Blinking display shows the start schedule for the 2
nd
operating period.
Fig. 29 Beginning of the 2
nd
operating period
▶ Use the „+“ and „-“ keys to set the operating start schedule
of the 2
nd
period.
▶ Press „ok“.
Blinking display shows the operating stop schedule for the
2
nd
period.
▶ Use the „+“ and „-“ keys to set the operating duration.
▶ Press „ok“.
Days „1 to 5“ are now set.
Fig. 30 Start of 1st operating period for days „6 to 7“
Days 1, 2, 3, 4 and 5 corresponds to
Monday, Tuesday, Wednesday, Thursday
and Friday, respectively. Days 6 and 7
corresponds to Saturday and Sunday (
Section 5.10).
If the start of the 2
nd
operating period is set
within the operating period of the 1
st
period,
the end of operation of the 1st period will be
adjusted to the newly defined value.
If there‘s no need for a 2nd working period:
▶ Select the start schedule and end of