Pre-installation | 17
6 720 ... ... (YYYY/MM)Product Name
Service interval
4 Pre-installation
4.1 Cleaning primary systems
4.2 Hydraulic connections
4.2.1 Connecting flow and return
Fig. 11 Pipe work connector location
Regular boiler:
[1] Hot water flow (1”)
[2] Gas (3/4”)
[3*] Not use on the Regular boiler
[4] Hot water return (1”)
[5] Condensate outlet
System boiler:
[1] Heating and DHW flow (1”)
[2] Gas (3/4”)
[3*] DHW return (1”) (only if optional diverter valve kit is fitted)
[4] Heating return (1”)
[5] Condensate outlet
NOTICE: Damage to the system caused by a lack of or
insufficient cleaning and servicing.
Get the heating system inspected at least annually by
an authorised heating engineer
Carry out a service as required. Carry out any repairs
immediately to avoid any damage to the system
NOTICE: Before installation
All the following Pre-Installation sections must be
read and requirements met before starting boiler or
flue installations.
CAUTION: MAINS POWER
ISOLATE THE MAINS SUPPLIES BEFORE STARTING
ANY WORK AND OBSERVE ALL RELEVANT SAFETY
PRECAUTIONS.
NOTICE: Protect the boiler
Debris from the system can damage the boiler and
reduce efficiency.Failure to comply with guidelines
for the use of water treatment with the appliance will
invalidate the appliance warranty.
WARNING: Sealing agents
The addition of sealing agents to the system water is
not permitted, this can cause problems with deposits
left in the heat exchanger.
NOTICE: Damage to property caused by leaking
connections:
Ensure the pipes are installed without mechanical
strain onto the appliance connections
Refurbish seals when loosening or removing
connection joints
Check gaskets and connections for signs of damage
We recommend the installation of a line strainer in
the system return to protect the heating system
Fit isolating valves before and after the line strainer
to allow for servicing
Fit isolation valves in the flow and return to allow
servicing of the appliance
6720809859-10.1Wo
123*4
61
78 111
Ø125
5
83
59