28 | COMMISSIONING
Product Name6 720 ... ... (YYYY/MM)
Commissioning Page Unit Values Comment
1 Fill the heating system and check for leaks
2 Record gas values
Wobbe index
Calorific value
kWh/m
3
3 Check gas supply for leaks
Bleed gas supply
4 Pressurise the heating system and record the value bar
5 Check the flue inlet and exhaust, and connections
6
7 Set the gas type, if required
8 Commission burner and controls
9 Measure and record gas supply pressure mbar
10 Measure flue gas values and record Full load Partial load
- Flue gas pressure Pa
- Flue gas temperature (gross) t
A
°C
- Air temperature t
L
°C
- Flue gas temperature (net) t
A
- t
L
°C
- CO
2
or O
2
content Vol. %
- Flue gas losses q
A
%
- CO content (air free) ppm
- Supply air CO
2
or O
2
content when operating room sealed Vol. %
11 Check for leaks during operation
12 Functional tests
Measure ionisation current
13 Refit casing panels
14 Inform homeowner and hand over documentation
15 Correct installation by approved installer Signature
16 Homeowner Signature
Table 16 Commissioning checklist