6 720 646 196 (2013/08) Condens 5000 W
10 | System pressure
4.2 External filling loop
Once the external filling loop has been located, follow the instructions for re-pressurising the system.
1. Unscrew blanking cap.
2. Attach the hose to the valves, screw on hand-tight.
3. Turn the handle/screwdriver slot through 90° to open the valves.
4. The handle/screwdriver slot will be in-line with the valves
Fig. 7 External filling loop
5. When the pressure reaches between the 1 and 1.5 bar marks (zone A), turn the handle/screwdriver slot back, through 90°, to
close the valve.
6. The handle/screwdriver slot will be at 90° to the valves
7. Remove the hose and replace the blanking caps.
External filling loop valve must be installed according to local authorities regulations to protect the potable water
supply.
6720643356-12.2Wo
1.
2.
7.
3.
3.
4.4.
5.
5.
6.6.
2
3
1
04
bar