Technical Specifications/Logs
63
Bosch Condens 5000W – 6 720 646 195 (2018/10)
8.2 Inspection and maintenance checklist
Table 22 Inspection and maintenance checklist
The inspection and maintenance checklist also serve as a master copy.
▶ Sign and date the completed inspection work.
Date:
1 Check boiler operation (CH & DHW) and fault history. Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
2 Visual inspection:-
Check compliance of boiler, system and components.
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
3 Internal visual inspection:-
Check for signs of leaking, corrosion and distress.
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
4 Perform a visual check of the air/flue gas routing. Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
5 Check gas supply pressure. mbar (kPa)
6 Check Fan pressure test. Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Was cleaning required? No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
6.1 If cleaning was required check the following:
Heat exchanger Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Burner Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Electrodes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Diaphragm in mixer unit Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
7 Check and clean syphon Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
8 Check the gas-air ratio at min./max. and
adjust if necessary.
min. %
max. %
9 Check the expansion vessel pre-charge
pressure matches the static head of the
heating system.
bar (kPa)
10 Check the heating system pressure. bar (kPa)
11 Check electrical wiring for damage. Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
12 Check the heating controller settings. Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
13 Boiler left to customers settings Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
14 Signature