Appendix
65
Condens 7000 F – 6720871560 (2019/11)
Table 25 Inspection and maintenance record
If any condition requiring maintenance is identified in the course of the
inspection, this work must be carried out as required.
The requirements for replacement of gaskets are detailed in
Chapter 11.11.3, page 42.
12. Recording measurements: 29
• Discharge pressure
________Pa ________Pa ________Pa ________Pa
• Gross flue gas temperature t
A
________ °C ________ °C ________ °C ________ °C
• Air temperature t
L
________ °C ________ °C ________ °C ________ °C
• Net flue gas temperature t
A
- t
L
________ °C ________ °C ________ °C ________ °C
• Carbon dioxide content (CO
2
)
or oxygen content (O
2
) _________% _________% _________% _________%
• CO content, air free
_______ppm _______ppm _______ppm _____ppm
13. Carry out function checks: 29
• Check ionisation current.
________µA ________µA _______µA ______µA
• Test the differential pressure switch. 54
14. Check for leaks during operation. 30
15. If necessary, check function of installed water
treatment cartridge and check for wear.
16. Check that the control unit is set correctly in line with
demand (see documents for the control unit).
–
17. Final check of servicing work –
Confirm correct inspection
Company stamp/date/signature
Inspection work Page Full Load Partial load Full Load Partial load